JZJ-TP80 Explosion-Proof Handheld Thermal Imaging Thermometer
- Commodity name: JZJ-TP80 Explosion-Proof Handheld Thermal Imaging Thermometer
Email:
15010482279@139.com
- Product Description
-
Features and Capabilities
Explosion-proof rating:
- Explosion-proof design: Intrinsically safe
- Explosion-proof marking: Ex ic IIC T6 Gc
- Original resolution 256 × 192, high-sensitivity vanadium oxide uncooled detector
- Supports timed and temperature-difference shutter correction.
Thermal imaging image:
- Supports 3D noise reduction and image detail enhancement features.
- Supports 4 adjustable pseudo-color modes
Temperature anomaly alarm function:
- Temperature measurement accuracy: ±2 °C or ±2% of reading (whichever is greater) | Dual-light fusion: Supports thermal imaging and visible-light dual-light fusion | Features center-point, maximum temperature, and minimum temperature measurements
- Temperature measurement range: -20 °C to 550 °C
System features:
- Standby time > 6 hours, with automatic shutdown and power-saving mode supported.
- The image stores full-screen temperature measurement data and supports offline temperature analysis (when used with the client application).
Specification parameters
Model
JZJ-TP80
Thermal imaging
Sensor Type
Non-cooled vanadium oxide microbolometer
Detector resolution
256 × 192
Response Band
8–14 μm
NETD (Noise Equivalent Temperature Difference)
<50 µm (@25 °C, F#=1.0)
Maximum image size
240 × 320
Minimum focusing distance
0.3 m
Field of view
37.2° × 50.0°
Frame rate
25 Hz
Pixel size
12 μm
F-value
F1.0
Minimum measurement distance
0.3 m
Temperature measurement unit
Celsius, Fahrenheit, Kelvin
Temperature measurement range
-20 °C to 550 °C
Accuracy
±2 °C or ±2% of the reading (whichever is greater)
Spatial resolution (IFOV)
3.3mrad
Visible light
Resolution
1600 × 1200
Field of view
55° × 42°
Maximum image size
1600 × 1200
Image resolution
1600 × 1200
The image shows
Display monitor
3.2-inch LCD screen (240 × 320)
Image Mode
White-hot, black-hot, iron-red, rainbow
Screen Display Mode
Fusion, thermal imaging, visible light, Picture-in-Picture
Maximum image size
240 × 320
Frame rate
25 Hz
Image format
JPEG image with temperature measurement data, supporting offline analysis on the client side
System Functions
UVC Screen Mirroring
Support
Lighting
Support
Alarm linkage
Supports audio alarms, visual alarms, image-based alerts, and alarm notifications.
Temperature Measurement Rules
6 temperature measurement points (center point, highest temperature, lowest temperature, and 3 custom points)
Storage
16 GB built-in eMMC
Power interface
Type-C Direct Charging
Battery Type
Rechargeable lithium-ion battery
Charging time
< 3 h @ 25 °C
Battery operating time
> 6 h @ 25 °C
Power Management
Adjustable; Off—5 minutes, 10 minutes, 20 minutes
System parameters
Operating temperature and humidity
-20 °C to 50 °C, ≤95%
Storage temperature and humidity
-20 °C to 60 °C, ≤95%
Protection Level
IP54
Drop Resistance Rating
2 m
Weight
380 g (including battery)
Applicable gas environment
Level
T1 (450 °C)
T2 (300 °C)
T3 (200 °C)
T4 (135 °C)
T5 (100 °C)
T6 (85 °C)
II A
Methane, toluene, methyl ester, ethane, acetone, acrylic acid, benzene, styrene, carbon monoxide, ethyl acetate, acetic acid, chlorobenzene, methyl acetate, ammonia
Propane, methanol, ethanol, ethylbenzene, propanol, propylene, butanol, butane, butyl acetate, amyl acetate, cyclopentane,
Pentane, pentanol, hexane, hexanol, heptane, octane, cyclohexanol, turpentine, naphtha, petroleum (including gasoline), fuel oil, pentanol tetrachloride
Acetaldehyde, Trimethylamine
Ethyl nitrite
II B
Propyne, acrylonitrile, dimethyl ether, hydrogen cyanide, and city gas
Butadiene, ethylene oxide, ethylene, furan
Dimethyl ether, acrolein, hydrogen sulfide
Di-n-butyl ether, diethyl ether, ethyl methyl ether, tetrafluoroethylene
Ⅱ C
Hydrogen, water gas
Acetylene
Carbon disulfide
Ethyl nitrate
*The equipment must not be used in gas environments outside the ranges specified in the table above.
Ordering Model
JZJ-TP80
External dimensions

Keywords:
Honorary Qualifications
Frequently Asked Questions
Can't charge the device?
The device may have been left unused for too long, causing the battery to lose charge. You can try charging it for an extended period. If there’s still no response, we recommend sending it in for repair. Also, please use the dedicated charger provided for each device when charging.
Can't connect the thickness gauge's flat plate to the instrument?
First, turn on the tablet’s hotspot and check whether the eight-digit number in the hotspot name matches the eight-digit SN code of the device. If they don’t match, make the necessary adjustments. Then, follow the instructions in the manual to connect the tablet. If you’re still unable to proceed, we recommend contacting customer support for assistance.
How can I fix the issue of fluctuating readings during thickness measurement?
It is recommended to connect the flat plate during the thickness measurement process and observe the waveform. If the waveform appears poor, switch to manual mode for inspection. If no consistent waveform is detected, consider potential material issues or probe damage—replace the probe and try again. If no waveform still appears after replacing the probe, the material itself may be of poor quality, making it unable to generate an effective signal.