JZ.J-60
Multi-channel Imaging Wireless Transmission Series
The pinnacle of perfect balance between performance and portability
- Commodity name: JZ.J-60
Email:
15010482279@139.com
- Product Description
-
Oxide Scale Accumulation Detector
Ultra-(Ultra-)Supercritical Power Plant Boiler
Austenitic Stainless Steel Oxide Scale Accumulation Detection
Technical indicators
- Windows system, memory: 4GB, USB port
- System sensitivity: 1 mV
- Applicable pipe diameter: 1–140 mm
- Measurement range: The measurement range is no less than 4900 mV, with real-time display and automatic zeroing capability.
- Repeatability: Repeatability error is less than 10 mV under demagnetization conditions.
- Zeroing Function: Features an automatic on-site zeroing capability (no sample tube required)
- Data storage capacity: 64GB; capable of storing 10,000 imaging images and associated data
- The sensor and host use a wireless connection mode.
- Channel count: 6-channel Hall sensors operate simultaneously, displaying data on the same screen.
- Position Detection: Utilizing a high-precision accelerometer, this system is designed for pipeline inspection on complex surfaces, achieving a displacement accuracy of 1 mm.
- Software; sensors operate independently in each channel, and the detection results can be displayed as waveforms, data, images, or percentages.
- Display: TFT True Color Screen; Built-in Resistive Touchscreen Controller; Supports Single-Touch (Hand & Pen) Interactions
- Operating temperature: -25°C to +60°C



Oxide scale
Pipe rupture caused by oxide scale buildup
Main Features
- Threshold: Multiple alarm thresholds for easy calculation of blockage levels; detection results within different value ranges are displayed in real time using distinct colors.
- Multi-channel sensor: Equipped with a fully covering 6-channel sensor array, ensuring reliable signal reception regardless of the pipeline's angle during inspection.
- Detection data: Displays real-time, on-screen data for the current tube bundle.
- Real-time imaging: Real-time analysis of the object under inspection, displaying waveforms from each channel, B-scan images, and blockage percentages.
- Wireless Transmission: The host probe features a detachable design and uses wireless communication for detection, eliminating cable obstructions and making on-site operations more convenient.
- Acceleration sensor: Equipped with a high-precision accelerometer to prevent inaccurate position tracking caused by uneven pipe surfaces.
- Radius probe: Effectively couples with the stainless steel pipe being inspected, and the probe is suitable for detecting all pipe diameters.
- Database: Includes built-in characteristic signals for blockages in pipes of various specifications from major boiler manufacturers, reducing on-site equipment calibration time and enhancing ease of use.
Configuration
Military-grade three-proof host; wireless probe; stylus; USB data cable; dedicated charger; shoulder strap; instrument case
Keywords:
Honorary Qualifications
Frequently Asked Questions
Can't charge the device?
The device may have been left unused for too long, causing the battery to lose charge. You can try charging it for an extended period. If there’s still no response, we recommend sending it in for repair. Also, please use the dedicated charger provided for each device when charging.
Can't connect the thickness gauge's flat plate to the instrument?
First, turn on the tablet’s hotspot and check whether the eight-digit number in the hotspot name matches the eight-digit SN code of the device. If they don’t match, make the necessary adjustments. Then, follow the instructions in the manual to connect the tablet. If you’re still unable to proceed, we recommend contacting customer support for assistance.
How can I fix the issue of fluctuating readings during thickness measurement?
It is recommended to connect the flat plate during the thickness measurement process and observe the waveform. If the waveform appears poor, switch to manual mode for inspection. If no consistent waveform is detected, consider potential material issues or probe damage—replace the probe and try again. If no waveform still appears after replacing the probe, the material itself may be of poor quality, making it unable to generate an effective signal.