AT-2618

Bolt elongation, axial load, and mechanical stress testing
Dual-mode measurement: EMAT, PET
Wide detection range: Suitable for bolts from M6x16 to M36x300
Surface measurement requires no cleaning
Upper-level PC Analysis for Data Transmission
  • Commodity name: AT-2618

Email:

15010482279@139.com

  • Product Description
  • Bolt Stress Tester
     

    • The AT 2618 Bolt Tension Tester uses ultrasonic technology to accurately measure the mechanical stress in bolts during tightening.
    • It performs measurements without damaging the bolt. The device can simultaneously display clamping force, tension, and bolt elongation.
    • This instrument features two independent measurement channels. Both channels support both longitudinal and transverse wave measurements, enhancing accuracy while also significantly expanding the range of bolt sizes that can be accommodated compared to single-channel devices.

    Equipment Features

    • Measuring bolt elongation, axial load, and mechanical stress
    • Measurement modes: EMAT, PET
    • Suitable for bolts ranging from M6x16 to M36 x300
    • Axial load measurement range: from 0.1 ton to 100 tons
    • Measurements can still be taken even if the bolt surface has a non-conductive coating.
    • Connect to a PC for data transfer and reporting

    Instrument parameters

    Operating temperature range

    -20…+50°C

    Bolt surface operating temperature range

    -20…+50°C

    Continuous working hours

    8 hours

    Sound Speed Range Setting

    1000...9999 m, with a step size of 1 m/s

    Maximum measurements per second

    16

    Dimensions

    260x190x68mm

    Bolt length range

    16 mm - 300 mm

    Bolt size range

    From M6x 16 to M36x 300

    Device operating frequency

    EMAT is 4 MHz, while PET ranges from 1 MHz to 20 MHz.

    Axial Load Measurement Range (tons)

    0.1 to 100

    Axial Load Measurement Range (kN)

    From 1 to 1000

    Average Elongation Measurement Error

    4%

    EMAT Waveform Type

    Transverse wave

    PET Waveform Types

    Longitudinal wave

    Screen

    High-brightness TFT LCD

    Dimensions

    7 inches

    Brightness

    Adjustable up to 900 cd/m²

    Threshold

    2 independently adjustable thresholds

    Gain

    0...120 dB, AGC mode

    Charging time

    4 hours

Honorary Qualifications

Quality Management System Certification Certificate

Quality Management System Certification Certificate (English Version)

Occupational Health and Safety Management System Certification Certificate

Occupational Health and Safety Management System Certification Certificate (English Version)

< 12 >

Frequently Asked Questions

Can't charge the device?


The device may have been left unused for too long, causing the battery to lose charge. You can try charging it for an extended period. If there’s still no response, we recommend sending it in for repair. Also, please use the dedicated charger provided for each device when charging.

Can't connect the thickness gauge's flat plate to the instrument?


First, turn on the tablet’s hotspot and check whether the eight-digit number in the hotspot name matches the eight-digit SN code of the device. If they don’t match, make the necessary adjustments. Then, follow the instructions in the manual to connect the tablet. If you’re still unable to proceed, we recommend contacting customer support for assistance.

How can I fix the issue of fluctuating readings during thickness measurement?


It is recommended to connect the flat plate during the thickness measurement process and observe the waveform. If the waveform appears poor, switch to manual mode for inspection. If no consistent waveform is detected, consider potential material issues or probe damage—replace the probe and try again. If no waveform still appears after replacing the probe, the material itself may be of poor quality, making it unable to generate an effective signal.