Temperature measurement range: -20°C to 650°C
3.5-inch touch sunlight-readable screen
Supports point, line, and box temperature measurement
The image stores full-screen temperature measurement data and supports offline temperature analysis (when used with the client application).
Support for ledgers, ISR upscaling, remote album image transmission, and hybrid mode.
  • Commodity name: JZJ-SCB6-15

Email:

15010482279@139.com

  • Product Description
  • Handheld thermal imaging thermometer

    Electricity

    Petroleum and Petrochemicals

    Coal Mining and Metallurgy

    Rail Transit

    Large machinery

    Product Overview

    The Beijing PrecisionCheck handheld thermal imaging thermometer is a powerful tool capable of accurately measuring the temperature of high-heat targets in various environments. It helps on-site personnel quickly identify and troubleshoot issues, supports informed decision-making, and ensures safety—making it the ideal solution for industries such as power, construction, electrical engineering, and mechanical maintenance, where temperature monitoring is critical. With its versatile lens options, combined with a built-in database and intelligent diagnostic system, the device seamlessly handles inspection tasks and real-time status analysis for power and manufacturing companies. A top choice for professionals seeking precision and reliability.

    Application areas

    Suitable for applications such as distribution cabinet inspection, electrical patrols, and automotive repair. The thermal imaging field of view—50° x 50°—easily covers the target object.

    Detailed specifications

    Thermal imaging

    Sensor Type

    Non-cooled detector

    Detector resolution

    640x512 (327,680 pixels)

    Response Band

    7.5–14 μm

    NETD (■Acoustic Equivalent)
    Temperature difference)

    <0.03℃ (30 mK @ 25℃, 77°F, F#=1.0)

    Maximum image size

    640x480

    Infrared Image Resolution

    640x480 (307,200 pixels)

    Minimum focusing distance

    0.3m

    Field of view

    25 × x19 ×

    Lens Extension

    Magnification lenses (0.5X: 48.2° (H) x 36° (V), 2X: 12.3° (H) x 9.3° (V), 3X: 7.6° (H) x 5.7° (V))

    Digital Zoom

    Support. 1.0x–8.0x continuous

    Frame rate

    50Hz

    Focus Mode

    Automatic, Continuous Automatic, Laser-Assisted, Touch-to-Focus, Manual

    F-value

    F1.0

    Temperature measurement range

    -20°C to 150°C, 100°C to 650°C

    Accuracy

    t2°C or +2%, take the higher value

    Spatial Fraction
    (IFOV)

    0.68 milliradians

    Super-resolution

    Supports 1280x960 (1,228,800 pixels)

    Focus on speed

    About 2 seconds

    Visible light

    Maximum image size

    3264x2448

    Image resolution

    1600x1200

    Video resolution

    1600 x 1200

    The image shows
    System Functions

    Display monitor

    4.3" LCD Capacitive Touchscreen 800x480

    Image Mode

    Thermal imaging, visible light, fusion, picture-in-picture, Blending

    Pseudo-color Mode

    White heat, black heat, rainbow, iron red, red heat, fusion, rain, blue and red

    Manual AGC mode enabled
    The minimum temperature difference held

    2°C

    Color highlights

    High-Temperature Focusing / Low-Temperature Focusing / Range Focusing

    Laser Distance Sensing

    Indoor range: 50m Outdoor range: 15m

    Measurement and Threshold Rules

    Supports hotspot, cold spot, center point, 10-point measurement, 5-point measurement, 5-circle measurement, and 1-line temperature measurement.

    External Optical Correction

    Support

    UVQ Screen Mirroring

    Support, UVC Alarm Client

    Bluetooth

    Supports Bluetooth 4.2

    Location feature

    Not supported

    HDMI

    Not supported

    Laser pointer

    Supports, Class II, wavelength: 635 nm; power <1 mW

    Take a photo

    Thermal imaging, visible light, dual-light fusion, Blending

    Video recording

    Thermal imaging, visible light, dual-light fusion, Blending

    Lighting

    Support

    Electronic compass

    Not supported

    Text annotation

    Support, 255 English characters

    Ledger

    Supports use with the HIKMICRO Inspector.

    Interface Language

    Chinese

    4G

    Not supported

    Wi-Fi

    Supports 802.11 b/g/n (2.4 GHz and 5 GHz)

    Ranging accuracy

    0.1m

    Storage

    64GB, up to 128 GB

    Hardware interface

    USB Type-C

     

    Packing List

    1 battery (not included inside the device), 1 charging dock, 1 adapter, 1 wrist strap, 1 USB cable, 1 SD card, 1 lens cap, 1 accessory pouch
    Instruction manual x1, High-strength impact-resistant portable case x1

    Operating temperature and humidity

    -20°C to 50°C, ≤95%

    Protection Level

    IP54

    Security Level

    2m

    Weight

    Approximately 1000g (with lens, including battery)

    Dimensions

    285.2mm x 125.8mm x 120.6 mm

Honorary Qualifications

Quality Management System Certification Certificate

Quality Management System Certification Certificate (English Version)

Occupational Health and Safety Management System Certification Certificate

Occupational Health and Safety Management System Certification Certificate (English Version)

< 12 >

Frequently Asked Questions

Can't charge the device?


The device may have been left unused for too long, causing the battery to lose charge. You can try charging it for an extended period. If there’s still no response, we recommend sending it in for repair. Also, please use the dedicated charger provided for each device when charging.

Can't connect the thickness gauge's flat plate to the instrument?


First, turn on the tablet’s hotspot and check whether the eight-digit number in the hotspot name matches the eight-digit SN code of the device. If they don’t match, make the necessary adjustments. Then, follow the instructions in the manual to connect the tablet. If you’re still unable to proceed, we recommend contacting customer support for assistance.

How can I fix the issue of fluctuating readings during thickness measurement?


It is recommended to connect the flat plate during the thickness measurement process and observe the waveform. If the waveform appears poor, switch to manual mode for inspection. If no consistent waveform is detected, consider potential material issues or probe damage—replace the probe and try again. If no waveform still appears after replacing the probe, the material itself may be of poor quality, making it unable to generate an effective signal.