ORIMAG-C1
- Commodity name: ORIMAG-C1
Email:
15010482279@139.com
- Product Description
-
Ferromagnetic Material Structural Safety Assessment Analyzer
The ORIMAG-C1 Ferromagnetic Material Structural Safety Assessment Analyzer is a portable, non-destructive testing device specifically designed to evaluate residual stresses and mechanical properties in ferromagnetic materials. It can be used to assess the level of residual stress, determine the fatigue status of ferromagnetic materials, measure surface hardness, and evaluate the quality of surface treatments applied to these materials. This versatile tool finds applications across various industries—including power generation, railways, metallurgy, mechanical manufacturing, bridge construction, oil and gas pipelines, petrochemicals, and aerospace—for the safe diagnosis and evaluation of ferromagnetic metal components. Additionally, it can also be employed to assess the metallurgical process quality of ferromagnetic materials.
The ORIMAG-C1 is easy to operate—both the main unit and the probe allow for measurement operations and data display, while the system automatically saves all measurement data. Additionally, the device features hot-plug detection, enhancing its overall safety and reliability.






Detection object: Pipeline plugging
Full-Surface Stress Distribution Diagram for Sealing
Weld seam Number
Measurement Point Area Room Number
Measurement point location
Measurement point location
Straight section Side Heat Affected Zone
Weld seam
Elbow Side Heat Affected Zone
Straight-section side thermal shadow Sound Zone
Weld seam
Elbow-side thermal shadow Sound Zone
G2

1-2
20.2
25.7
14.1
2-3
19.6
25.2
13.8
3-4
14.7
27.1
14.3
4-5
19.6
27.4
15.2
5-6
19.0
28.2
14.8
6-7
18.9
28.7
14.4
7-8
18.7
29.6
14.3
8-9
18.5
31.6
15.3
9-10
18.7
29.4
14.1
10-11
19.1
28.6
13.3
11-12
18.5
28.6
13.6
12-13
18.5
29.3
13.6
13-14
20.0
28.4
15.1
14-15
20.0
29.7
14.7
15-16
20.2
28.4
14.4
16-17
19.5
29.0
13.9
17-18
19.7
29.5
15.2
18-19
20.5
28.5
15.3
19-20
19.0
29.1
14.7
20-21
19.0
28.3
14.0
21-22
19.1
27.3
14.1
22-23
19.6
28.0
14.6
23-1
20.8
28.4
17.1
Keywords:
Honorary Qualifications
Frequently Asked Questions
Can't charge the device?
The device may have been left unused for too long, causing the battery to lose charge. You can try charging it for an extended period. If there’s still no response, we recommend sending it in for repair. Also, please use the dedicated charger provided for each device when charging.
Can't connect the thickness gauge's flat plate to the instrument?
First, turn on the tablet’s hotspot and check whether the eight-digit number in the hotspot name matches the eight-digit SN code of the device. If they don’t match, make the necessary adjustments. Then, follow the instructions in the manual to connect the tablet. If you’re still unable to proceed, we recommend contacting customer support for assistance.
How can I fix the issue of fluctuating readings during thickness measurement?
It is recommended to connect the flat plate during the thickness measurement process and observe the waveform. If the waveform appears poor, switch to manual mode for inspection. If no consistent waveform is detected, consider potential material issues or probe damage—replace the probe and try again. If no waveform still appears after replacing the probe, the material itself may be of poor quality, making it unable to generate an effective signal.
Get a quote
*Note: We will contact you within 1 business day. Please check your email at 15010482279@139.com.